Image

Timber Frame

Non-loadbearing timber stud partitions

Timber frame construction is well established in the UK and British Gypsum products are used extensively to form the internal elements.

Timber frame internal partitions are used in both new-build and refurbishment projects, and are often specified as fire and sound resisting walls in residential applications to meet requirements of national building regulations.

Gyproc plasterboards are used to line the timber stud framing, and Isover insulation products can be used to further enhance the sound insulation performance.

42 Solutions

A026009 (EN)

One layer of Gyproc SoundBloc 12.5mm each side of 63 x 38mm timber stud (CLS) at 600mm centres. 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity.

Fire Insulation (mins)
30
Fire Integrity (mins)
30
Maximum Height (mm)
4000
Partition Thickness (mm)
88
Sound Insulation (Airborne) Rw (dB)
42

A026009 MR1 (EN)

One layer of Gyproc SoundBloc 12.5mm one side and one layer Gyproc SoundBloc MR 12.5mm the other side of 63 x 38mm timber stud (CLS) at 600mm centres. 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity.

Fire Insulation (mins)
30
Fire Integrity (mins)
30
Maximum Height (mm)
4000
Partition Thickness (mm)
88
Sound Insulation (Airborne) Rw (dB)
42

A026009 MR2 (EN)

One layer of Gyproc SoundBloc MR 12.5mm each side of 63 x 38mm timber stud (CLS) at 600mm centres. 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity.

Fire Insulation (mins)
30
Fire Integrity (mins)
30
Maximum Height (mm)
4000
Partition Thickness (mm)
88
Sound Insulation (Airborne) Rw (dB)
42

A026010 (EN)

One layer of Gyproc WallBoard 15mm each side of 63 x 38mm timber stud (CLS) at 600mm centres. 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity.

Fire Insulation (mins)
30
Fire Integrity (mins)
30
Maximum Height (mm)
4000
Partition Thickness (mm)
93
Sound Insulation (Airborne) Rw (dB)
40

A026010 MR1 (EN)

One layer of Gyproc WallBoard 15mm one side and one layer of Gyproc Moisture Resistant 15mm the other side of 63 x 38mm timber stud (CLS) at 600mm centres. 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity.

Fire Insulation (mins)
30
Fire Integrity (mins)
30
Maximum Height (mm)
4000
Partition Thickness (mm)
93
Sound Insulation (Airborne) Rw (dB)
40

A026010 MR2 (EN)

One layer of Gyproc Moisture Resistant 15mm each side of 63 x 38mm timber stud (CLS) at 600mm centres. 25mm Isover Acoustic Partition Roll (APR 1200) in the cavity.

Fire Insulation (mins)
30
Fire Integrity (mins)
30
Maximum Height (mm)
4000
Partition Thickness (mm)
93
Sound Insulation (Airborne) Rw (dB)
40